<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-22 01-26-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
5.5 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 67 kHz 17876 0,9118
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,4 dBr 3,66 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 12 kHz % above 76 kHz: 0,9118 Acquired: 2024/10/22 1.25.38 Total samples: 17876 Equivalent time: 0:14:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,3 dBr MIN: 2,4 dBr AVE: 3,66 dBr % above 12,2 dBr: 0,0 Last value: 3,2 dBr (2024/10/22 1.25.38) 01.12 01.14 01.16 01.18 01.20 01.22 01.24 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]